feat(bcn01-lab): onboard BCN01-LAB site and extend module with WAN2 support
- Add sites/BCN01-LAB with full Meraki configuration: VLANs, SSIDs, switch ports, 802.1X policy, firewall rules, WAN uplinks and warm spare - Extend modules/meraki-site to support wan2_* fields in mx_wan_uplinks Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Sonnet 4.6
parent
097a3c5b6c
commit
29614e1dc4
@@ -0,0 +1,29 @@
|
||||
locals {
|
||||
# Warm Spare (HA) — floating VIP between primary and spare MX
|
||||
mx_warm_spare = {
|
||||
enabled = true
|
||||
spare_name = "BCN01-F04-MX02"
|
||||
uplink_mode = "virtual"
|
||||
virtual_ip1 = "57.133.120.183" # Floating VIP on WAN1
|
||||
virtual_ip2 = "57.133.120.182" # Floating VIP on WAN2
|
||||
}
|
||||
|
||||
# Static WAN2 configuration for each MX (WAN1 disabled)
|
||||
# Device serials are resolved automatically from the display name
|
||||
mx_wan_uplinks = [
|
||||
{
|
||||
name = "BCN01-F04-MX01"
|
||||
wan2_static_ip = "57.133.120.181"
|
||||
wan2_static_subnet_mask = "255.255.255.240" # /28
|
||||
wan2_static_gateway_ip = "57.133.120.177"
|
||||
wan2_static_dns = ["8.8.8.8", "1.1.1.1"]
|
||||
},
|
||||
{
|
||||
name = "BCN01-F04-MX02"
|
||||
wan2_static_ip = "57.133.120.180"
|
||||
wan2_static_subnet_mask = "255.255.255.240" # /28
|
||||
wan2_static_gateway_ip = "57.133.120.177"
|
||||
wan2_static_dns = ["8.8.8.8", "1.1.1.1"]
|
||||
},
|
||||
]
|
||||
}
|
||||
Reference in New Issue
Block a user